Skip to main content
. 2014 Dec 12;3:37. doi: 10.1186/2047-217X-3-37

Table 1.

Summary of patient characteristics

TG119 Prostate Liver Head and neck
Number of beam angles 5 180 56 1983
Total number of beamlets 418 25,404 3678 2,257,507
Noncoplanar no no yes yes
Beamlet size [cm] 1 ×1 1 ×1 1 ×1 0.5 ×0.5
Voxel resolution (LR,AP,SI) [mm] (3.0, 3.0, 2.5) (3.0, 3.0, 3.0) (3.0, 3.0, 2.5) (3.0, 3.0, 5.0)
Voxel grid size (LR,AP,SI) (167,167,129) (184,184,90) (217, 217,168) (160,160,67)
Number of target voxels 7429 9491 6954 25,388
Number of voxels in patient 599,440 690,373 1,927,357 251,893
dataset size 25 MB 1.9 GB 560 MB 64 GB

Number of target voxels for the head and neck case is for the union of the three planning target volume (PTV) structures. AP = anterior-posterior, LR = left-right, SI = superior-inferior.