Skip to main content
. 2014 Dec 23;15(1):1172. doi: 10.1186/1471-2164-15-1172

Table 2.

False non-synonymous SNVs called by the different strategies, with reads generated from both exonic and non-exonic regions

Strategy False positive non-synonymous SNVs False negative non-synonymous SNVs
No contamination 0 228
Direct 47 251
Filtering 0 265
Combined 3 70

False non-synonymous SNVs called by the different strategies, and true non-synonymous SNVs missed by them, under the mH.len100.eL setting with 1:1 human-mouse mixing ratio and reads generated from both exonic and non-exonic regions of human chromosome 14 and mouse chromosome 12.