Skip to main content
. 2013 Sep 6;27(10):898–906. doi: 10.1007/s12149-013-0768-7

Table 3.

Discrimination between AD converter and non-converter in MCI by baseline 123I-IMP-CBF SPECT

Type of analysis Sensitivity Specificity PPV NPV Accuracy
Central image interpretation 76 % (75/99) 39 % (44/113) 52 % (75/144) 64 % (4 4/68) 56 % (119/212)
Automated ROI analysis 81 % (80/99) 37 % (42/113) 53 % (80/151) 69 % (42/61) 58 % (122/212)

PPV positive predictive value, NPV negative predictive value