Skip to main content
. Author manuscript; available in PMC: 2015 Feb 16.
Published in final edited form as: Circ Arrhythm Electrophysiol. 2014 Feb 14;7(2):244–250. doi: 10.1161/CIRCEP.113.000548

Table 2.

Comparison of Procedural Variables Between Patients With Different Percutaneous Left Ventricular Assist Devices During Ventricular Tachycardia Ablation

IABP (N=22) Non-IABP Combined
(N=44)
Non-IABP Subgroups Total (N=66) P Value (IABP vs
Non-IABP)

Impella (N=25) TandemHeart (N=19)
No. of VTs induced
  Mean±SD 3.3±1.5 3.1±1.9 2.5±1.7 3.9±1.8 3.2±1.8 0.733
  Median (min–max) 3 (1–7) 3 (0–7) 2 (0–7) 4 (2–7) 3 (0–7) 0.556
No. of nonclinical VTs induced
  Mean±SD 1.2±1.1 1.0±1.5 0.64±1.1 1.7±1.9 1.1±1.4 0.721
  Median (min–max) 1 (0–4) 0.5 (0–6) 0 (0–5) 1 (0–6) 1 (0–6) 0.209
No. of VTs ablated
  Mean±SD 1.8±1.0 2.4±1.3 1.9±1.1 3.0±1.2 2.2±1.2 0.074
  Median (min–max) 1 (1–4) 2 (1–6) 1 (1–5) 3 (1–6) 2 (1–6) 0.084
No. of unstable VTs mapped and ablated
  Mean±SD 0.32±0.48* 1.05±0.78* 1.12±0.83 0.95±0.70 0.80±0.77* <0.001*
  Median (min–max) 0 (0–1)* 1 (0–3)* 1 (0–3) 1 (0–2) 1 (0–3)* <0.001*
No. of VTs RF terminated
  Mean±SD 0.91±0.81* 1.59±1.00* 1.16±0.85 2.16±0.90 1.36±0.99* 0.007*
  Median (min–max) 1 (0–4)* 1 (0–4)* 1(0–3) 2 (1–4) 1 (0–4)* 0.003*
Entrainment/activation mapping, % 13 (59)* 36 (82)* 20 (80) 16 (84) 49 (74)* 0.046*
External rescue shocks
  Mean±SD 3.0±1.5* 1.9±2.2* 1.6±2.8 2.3±1.2 2.3±2.0* 0.049*
  Median (min–max) 3 (0–6)* 2 (0–13)* 1 (0–13) 2 (1–5) 2 (0–13)* 0.003*
Fluoro time, min, median (Q1–Q3) 63 (52–72) 63 (53–73) 68 (54–74) 58 (48–70) 63 (53–73) 0.935
RF time, min, median (Q1–Q3) 36 (27–45) 31 (18–41) 36 (13–50) 28 (19–37) 34 (23–43) 0.142
Procedure time, min, median (Q1–Q3) 302 (242–345) 339 (260–417) 291 (247–346) 379 (328–433) 327 (253–410) 0.185
Ventilation time, h, median (Q1–Q3) 16 (12–25) 12 (6–24) 6 (5–29) 20 (12–24) 15 (8–24) 0.121

IABP indicates intra-aortic balloon pump; RF: Radiofrequency; and VT, ventricular tachycardia.

*

Statistically significant.