Figure 3

Cholinergic mEPSCs were altered 24 h after sevoflurane exposure. (a) While neurons were held on −70 mV in voltage-clamp mode, mEPSCs traces were recorded in each group in the presence of TTX and PTX. (b) 24 h after sevoflurane exposure, frequency of mEPSc was significantly reduced when compared to control (P < 0.05, n = 6, N = 24), (c) while the amplitude of mEPSCs was not changed (P > 0.05, n = 6, N = 24).