Skip to main content
. Author manuscript; available in PMC: 2015 Feb 18.
Published in final edited form as: J Vasc Surg. 2014 Jun 21;60(5):1146–1152. doi: 10.1016/j.jvs.2014.05.046

Table II.

Demographic and clinical characteristics and mortality in patients with early (perioperative) aneurysm ruptures

Patient No. Operative indicationa EVAR devicea AAA Diameter, cma Endoleak typeb Repair typeb Mortality at end of follow-up
1 Elective Medtronic 5.8 I EV Died within 30 days
2 Elective Zenith 5.2 None EV Died within 1 year
3 Symptomatic AAA Gore 6.2 None EV Died within 30 days
4 Elective Gore 6.0 None OR Alive
5 Ruptured AAA Medtronic 6.8 III EV Alive

AAA, Abdominal aortic aneurysm; EV, endovascular; EVAR, endovascular aortic aneurysm repair; OR, open repair.

a

At initial EVAR. Devices from Medtronic Vascular, Santa Rosa, Calif; Cook Zenith, Bloomington, Ind; and W. L. Gore & Associates, Inc, Flagstaff, Ariz.

b

At time of AAA rupture.