Table 1.

Relative radiation level designations

Relative Radiation Level Adult Effective Dose Estimate Range (mSv) Pediatric Effective Dose Estimate Range (mSv)
0 0
<0.1 <0.03
☢ ☢ 0.1–1 0.03–0.3
☢ ☢ ☢ 1–10 0.3–3
☢ ☢ ☢ ☢ 10–30 3–10
☢ ☢ ☢ ☢ ☢ 30–100 10–30

Note: Relative radiation level assignments for some of the examinations cannot be made, because the actual patient doses in these procedures vary as a function of a number of factors (eg, region of the body exposed to ionizing radiation, the imaging guidance that is used). The relative radiation levels for these examinations are designated as “Varies.”