Table 5.

Combinations of clinical features and predicted probabilities of CIED infection (N=128)

Device Type >1 Device-
related Procedure
SAB ≥4
days
Risk Score # SAB
cases
# Infected
cases
Predicted
Probability
ICD No No 0 29 1 0.07
ICD No Yes 5 21 7 0.29
ICD Yes No 3.5 7 2 0.20
ICD Yes Yes 8.5 6 3 0.58
PPM No No 4 23 5 0.23
PPM No Yes 9 27 17 0.62
PPM Yes No 7.5 7 4 0.49
PPM Yes Yes 12.5 8 6 0.84

Abbreviations: CIED = cardiovascular implantable electronic device, ICD = implantable cardioverter-defibrillator, PPM = permanent pacemaker, SAB: S. aureus bacteremia, # SAB cases = patients in current study with combination of features listed, # Infected Cases = number of patients with CIED infection in our cohort, PP = predicted probability of CIED infection from multivariable model.

Risk Scores: We assigned 4 points for PPM device, 3.5 points assigned for >1 device-related procedure, 5 points assigned for duration of SAB ≥4 days, and 0 otherwise