Published in final edited form as: Med Image Comput Comput Assist Interv. 2010;13(0 3):666–673. doi: 10.1007/978-3-642-15711-0_83

Table 1.

(a) Average AUC and accuracy for CaP detection, compared to MRI-MRS alone, and ScEPTre [1] based data fusion, averaged over a total of 19 MRI-MRS studies using the 30 top-ranked eigen values, (b) Average CaP detection accuracy and AUC results of SeSMiK-GE and ScEPTre for different dimensions d ∈ {10, 20, 30}.

(a)
Method AUC Accuracy
T2w MRI 66.1 ± 1.5 61.9 ± 1.3
MRS 82.6 ± 1.3 76.8 ± 1.3
ScEPTre 86.8 ± 1.26 78.2 ± 1.2
SeSMiK-GE 91.3 ± 0.2 83.0 ± 0.1
(b)
d AUC Accuracy
SeSMiK ScEPTre SeSMiK ScEPTre
10 89.8 ± 0.8 86.8 ± 0.9 84.2 ± 1.1 80.6 ± 1.3
20 90.7 ± 0.9 87.5 ± 0.8 84.6 ± 0.1 79.1 ± 1.2
30 91.3 ± 0.2 86.8 ± 1.26 83.0 ± 0.1 78.2 ± 1.2