Table 3.
The final multiple linear regression models to predict Cr(VI) concentrations measured in NJ Meadowlands district.
| Parameter estimate | Standardized estimate | P-value | Model/partial R2 | |
|---|---|---|---|---|
| ML (N = 64) | <0.0001 | 0.8080 (0.7829) | ||
| Intercept | −5.7835 | 0 | <0.0001 | – |
| Temperature | 0.0450 | 0.6302 | <0.0001 | 0.6779 |
| Relative humidity | 0.0277 | 0.3076 | 0.0005 | 0.0321 |
| Downwind direction | 0.5689 | 0.2267 | 0.0015 | 0.0311 |
| O3 | 0.0262 | 0.2655 | 0.0119 | 0.0259 |
| Fe | 0.0013 | 0.3328 | 0.0032 | 0.0114 |
| Mn | −0.0692 | −0.3261 | 0.0106 | 0.0296 |
R2 value in parenthesis means the adjusted R2 in the model.