Skip to main content
. 2015 Feb 26;71(Pt 3):534–540. doi: 10.1107/S1399004714027643

Table 1. Crystal ‘hits’ when screening with MIPs.

Three MIPs were utilized for the screening of four model proteins. Details of all crystal ‘hits’ obtained in the presence of MIPs using Crystal Screen HT whilst the corresponding control drops remained clear are tabulated. The presence and absence of crystals is indicated by ‘Yes’ and ‘No’, respectively.

  MIP sample
Screen condition Haemoglobin-MIP Lysozyme-MIP Trypsin-MIP
Thaumatin at 30mgml1
9 No No Yes
16 Yes No No
17 Yes No No
22 Yes No Yes
28 No Yes Yes
30 Yes Yes No
31 Yes No Yes
32 No Yes Yes
33 No Yes Yes
38 No No Yes
62 Yes No Yes
75 No Yes Yes
76 No Yes Yes
80 Yes Yes No
89 Yes No No
Lysozyme at 30mgml1
4 Yes Yes Yes
14 No Yes No
16 Yes No No
18 No No Yes
43 Yes No No
45 Yes No No
46 No Yes Yes
60 No Yes Yes
73 Yes Yes No
75 Yes Yes Yes
78 No Yes Yes
94 No No Yes
Trypsin at 50mgml1
14 Yes Yes Yes
42 Yes Yes Yes
43 Yes Yes Yes
46 Yes Yes Yes
Haemoglobin at 50mgml1
45 Yes No No
82 Yes No No