Skip to main content
. 2015 Jan 20;593(Pt 5):1083–1111. doi: 10.1113/jphysiol.2014.279232

Table 7.

Mean ± SD for the Niederer model parameters giving mouse, rat and human output metric values

Mouse data Rat data Human data
Using the
Using the Grandi–
Using the Using Using the Using Beuckel- Using Pasqualini– Using the Using the
measured synthetic Ca measured Ca synthetic mann Ca synthetic Bers Ca Ten Tusscher O'Hara–Rudy
Ca transient transients transient Ca transients transient Ca transients transient Ca transient Ca transient
Parameter (n = 7*) (n = 3) (n = 63) (n = 46) (n = 52) (n = 31) (n = 6) (n = 99) (n = 122)
Ca50ref 0.34×10–3 ±  0.34×10–3 ±  1.89×10–3 ±  1.78×10–3 ±  1.11×10–3 ±  1.60×10–3 ±  1.1×10–3 ±  2.0×10–3 ±  0.93×10–3 ± 
2.03×10–5 2.4×10–5 3.4×10–4 3.79×10–4 1.57×10–4 2.53×10–4 4.0×10–4 6.4×10–5 6.2×10–5
krefoff 0.11 ± 0.03 0.07 ± 0.01 0.13 ± 0.05 0.17 ± 0.09 0.28 ± 0.08 0.21 ± 0.03 0.17 ± 0.07 0.11 ± 3.2×10–3 0.29 ± 0.04
kon 230.10 ± 44.80 234.20 ± 34.90 194.6 ± 95.4 188.0 ± 91.9 271.1 ± 130.6 330.1 ± 113.2 299.9 ± 79.3 212.0 ± 6.20 240.9 ± 73.5
nr 1.78 ± 0.33 1.64 ± 0.81
β0 0.40 ± 0.36 0.60 ± 0.52
β1 −1.30 ± 0.10 −1.50 ± 0.26
γ 4.39 ± 0.40 3.82 ± 0.98 2.14 ± 0.40 2.75 ± 1.29 2.46 ± 0.82 1.68 ± 0.52 1.08 ± 0.05 1.02 ± 0.01 1.74 ± 0.26
nH 12.22 ± 1.34 14.05 ± 0.92 7.74 ± 2.18 8.27 ± 3.35 10.08 ± 2.07 11.22 ± 2.21 6.17 ± 1.60 7.32 ± 0.21 13.66 ± 0.80
Tref 122.00 ± 11.20 115.30 ± 13.00 111.7 ± 14.2 112.0 ± 15.2 118.9 ± 12.8 119.2 ± 13.2 107.0 ± 17.0 92.2 ± 1.79 104.2 ± 7.98
α0 0.04 ± 0.01 0.04 ± 0.02 0.08 ± 0.04 0.12 ± 0.09 0.26 ± 0.11 0.31 ± 0.06 0.41 ± 0.12 0.08 ± 2.4×10–3 0.28 ± 0.03
αr1 0.38 ± 0.08 0.37 ± 0.11 0.11 ± 0.04 0.16 ± 0.09 0.05 ± 0.01 0.07 ± 0.02 0.01 ± 2.2×10–3 0.01 ± 3.6×10–4 0.01 ± 9.0×10–4
αr2 0.01 ± 0.01 4.3×10–3 ± 6.0×10–3
Kz 0.07 ± 0.03 0.09 ± 0.04
Cad 0.22 ± 0.03 0.24 ± 0.07 103.2 ± 24.4
Camax 0.51 ± 0.03 1.73 ± 0.32 869.0 ± 92.2
τCa1 21.15 ± 0.81 26.45 ± 1.46 120.2 ± 7.4
τCa2 21.15 ± 0.81 26.45 ± 1.46 232.7 ± 13.3
*

n denotes the number of succeeding parameter sets. The parameters for which no results are given were not varied in the respective parameter fittings. The parameters β0 and β1 were not varied for rat and human, as only resting sarcomere length was used. Ca transient parameters are not given where the measured or fixed Ca transients were used.