Table 2.

Blood and material parameters used in the SA-MDT system.

Properties Symbol Units Values
Applied field properties
 Magnitude μ 0 H 0 T 0.25, 0.50, 0.75, 1
 Angle of field direction θ π/2
Physical properties
 Temperature T K 300
 Boltzmann's constant k B J/K 1.38 × 1023
 Permeability of vacuum μ 0 Tm/A 4π × 10−7
MDCPs properties
 Polymer material P(S/V-COOH)Mag
 Radius R p μm 0.5
 MDCP concentration Particle/L 4 × 1010
 Density of the polymer material ρ pol,p kg/m3 950
 Initial distance between MDCPs μm 29.24
 Saturation magnetization M p,s kA/m 22.4
Stent properties
 Material SS 430
 Wire radius R wire μm 62.5
 Loop separation H cm 0.2
 Number of loops N l 10
 Coil length L cm 2
 Saturation magnetization M implant,s kA/m 1261
 Magnetic susceptibility X implant,0 1000
Blood and vessel properties
 Velocity u 0 cm/s 0.05, 0.1, 0.25, 0.5
 Volume V blood mL 10
 Density ρ b kg/m3 1000
 Viscosity η b kg/ms 1.0 × 10−3
 Vessel radius R vessel cm 0.05
Magnetic material properties
 Material Oleate-capped Fe3O4
 Weight content X fm,p wt% 100
 Density ρ fm,p kg/m3 5000
 Magnetic moment m fm,p Am2
 Saturation magnetization M fm,p,s kA/m See Table 1
 Diameter R fm,p nm See Table 1