Table 2. Results Table.

Table shows the Rmax, tmax, and tc values for all tissue phantom and frequency combinations. Results show a trend of decreasing Rmax, tmax, and tc with increase Young’s modulus and increasing frequency.

Frequency Material Rmax (μm) tmax (μs) tc (μs)
345 kHz
Water 617.2±61.8 75 200
E=1.13 kPa 600.1±70.9 65 190
E=21.7 kPa 398.8±102.5 40 150
E=242 kPa 216.1±22.3 20 64
E=570 kPa 163.9±37.2 12 40
500 kHz
Water 387.9±43.9 48 100
E=1.13 kPa 380.3±34.0 48 100
E=21.7 kPa 297.4±50.5 28 72
E=242 kPa 98.3±25.3 8.0 26
E=570 kPa 71.8±15.1 8.0 24
1.5 MHz
Water 114.1±18.9 12.0 36.0
E=1.13 kPa 111.5±14.5 14.0 32.0
E=21.7 kPa 79.5±11.5 10.0 32.0
E=242 kPa 42.1±7.9 5.0 12
E=570 kPa 20.6±4.1 1.0 5.0
3 MHz
Water 64.8±7.9 8.0 20
E=1.13kPa 65.2±7.0 8.0 18
E=21.7 kPa 34.3±8.5 5.0 10
E=242 kPa 18.0±5.3 3.0 7.0
E=570 kPa 11.0±4.4 1.0 2.5