Table 1.
Ref. | Year | Patients, n | Assay method | Assay system |
Assay results |
Quality score |
||||
TP | FP | FN | TN | STARD | QUADAS | |||||
Hochwald et al[42] | 1998 | 48 | MRCP, ERCP | 1.5 T machine | 19 | 3 | 1 | 25 | 15 | 11 |
Boraschi et al[43] | 1999 | 278 | MRCP, ERCP | 1.5 T MR unit | 71 | 5 | 5 | 197 | 16 | 11 |
de Lédinghen et al[44] | 1999 | 32 | EUS, MRCP, ERCP | 1 T system | 10 | 6 | 0 | 16 | 20 | 13 |
Lomas et al[45] | 1999 | 69 | MRCP, ERCP | 1.5 T MR system | 9 | 2 | 0 | 58 | 13 | 9 |
Varghese et al[46] | 1999 | 100 | MRCP, ERCP | 1.5 GE unit | 28 | 1 | 2 | 69 | 17 | 12 |
Stiris et al[47] | 2000 | 50 | MRCP, ERCP | 1.0 T | 28 | 1 | 4 | 17 | 17 | 12 |
Taylor et al[48] | 2002 | 129 | MRCP, ERCP | 1.5 T MR system | 45 | 9 | 1 | 74 | 18 | 12 |
Topal et al[49] | 2003 | 69 | MRCP, ERCP | 1.5 T MR system | 18 | 0 | 1 | 50 | 14 | 10 |
Kejriwal et al[50] | 2004 | 81 | MRCP, ERCP | Vision 1.5T MRI | 20 | 1 | 2 | 58 | 13 | 10 |
Simone et al[51] | 2004 | 65 | MRCP, ERCP, IOC | 1.0 T gyroscan NT | 13 | 6 | 8 | 38 | 13 | 9 |
Dalton et al[52] | 2005 | 69 | MRCP, ERCP, IOC | 1.5 T MR unit | 16 | 2 | 1 | 50 | 11 | 7 |
Hallal et al[53] | 2005 | 27 | MRCP, ERCP, IOC | Unknown | 4 | 2 | 0 | 21 | 14 | 10 |
Kondo et al[54] | 2005 | 28 | EUS, MRCP, HCT-C | 1.5 T MR system | 21 | 1 | 3 | 3 | 18 | 13 |
Moon et al[55] | 2005 | 29 | IDUS, MRCP, ERCP | 1.5T MR system | 16 | 1 | 4 | 8 | 17 | 11 |
Okada et al[56] | 2005 | 40 | CTCh, MRCP | 1.5 T system | 12 | 3 | 3 | 22 | 13 | 9 |
Shanmugam et al[57] | 2005 | 221 | MRCP, ERCP, EUS | 0.5 T MRI | 97 | 19 | 2 | 103 | 18 | 14 |
De Waele et al[58] | 2007 | 104 | MRCP, ERCP, EUS | 1.5 T unit | 19 | 2 | 4 | 79 | 16 | 11 |
Schmidt et al[59] | 2007 | 57 | MRCP, ERCP, EUS | 1 T magnet | 17 | 2 | 5 | 33 | 15 | 10 |
Hekimoglu et al[60] | 2008 | 269 | MRCP, ERCP | 1.5 T unit | 16 | 0 | 2 | 251 | 19 | 14 |
Nandalur et al[61] | 2008 | 95 | MRCP, ERCP | 1.5 T system | 21 | 1 | 7 | 66 | 18 | 13 |
Norero et al[62] | 2008 | 125 | MRCP, ERCP, CT | 1.5 T MR system | 83 | 10 | 3 | 29 | 15 | 11 |
Srinivasa et al[63] | 2010 | 117 | MRCP, ERCP, IOC | Siemens Vision 1.5 T | 15 | 2 | 8 | 102 | 16 | 12 |
Bilgin et al[64] | 2012 | 108 | MRCP, ERCP, IOC | 1.5 T MR scanner | 28 | 3 | 6 | 71 | 16 | 11 |
Zhang et al[65] | 2012 | 70 | MRCP, MDCT | 1.5 T MR system | 19 | 2 | 1 | 48 | 18 | 13 |
Mandelia et al[66] | 2013 | 30 | MRCP, USG | 1.5 T MR system | 19 | 1 | 1 | 9 | 17 | 12 |
CT: Computed tomography; CTCh: Cholangiography computed tomography; ERCP: Endoscopic retrograde cholangiopancreatography; EUS: Endoscopic ultrasonography; FN: False-negative; FP: False-positive; HCT-C: Helical-computed-tomographic cholangiography; IDUS: Intraductal ultrasonography; IOC: Intraoperative cholangiography; MDCT: Multidetector-row computed tomography; MR: Magnetic resonance; MRCP: Magnetic resonance cholangiopancreatography; QUADAS: Quality assessment for studies of diagnostic accuracy; STARD: Standards for reporting diagnostic accuracy; TN: True-negative; TP: True-positive; USG: Ultrasonography.