Table 1. Scanner and settings.

Hospital A Hospital B
Number of patients scanned 28 (patients 1 to 28) 8 (patients 29 to 36)
Scanner 64-slice scanner (sliding gantry Sensation 64, Siemens Medical Solutions, Forchheim, Germany) 128-slice scanner (Philips Brilliance iCT; Best, the Netherlands).
Total acquisition time 210 s 210 s
Standard Acquisition 1 image every 2 s for the first 48 s 1 image every 2 s for the first 48 s
Extended acquisition 60 s after start 1 image every 30 s 60 s after start 1 image every 30 s
Image acquisition parameters 80 kVp, 100 mAs 80 kVp, 100 mAs
Collimation 24 x1.2 mm 128 x 0.625 mm
Brain coverage 28.8 mm 40 mm to 80 mm
FOV 300 mm 220 mm
Reconstructed section width 4.8 mm 5.0 mm
Slice location At the level of the third ventricle At the level of the third ventricle
Contrast material Iopromide (Ultravist 300; Bayer HealthCare Pharmaceuticals, Pine Brook, New Jersey) Iopromide (Ultravist 300; Bayer HealthCare Pharmaceuticals, Pine Brook, New Jersey)
Contrast volume 40 ml followed by 40 ml of saline 40 ml followed by 40 ml of saline
Injection rate 4 ml/s via 18 G cannula in the right antecubital vein 6 ml/s via 18 G cannula in the right antecubital vein
Start of acquisition 7 seconds after the start of injection of contrast agent simultaneously with the start of injection of contrast agent