Skip to main content
. 2015 Mar 5;16(2):285–307. doi: 10.1007/s10162-014-0502-8

Table 1.

Cochlear implant (CI) subject demographics

Subject ID Age (years) Durationa of hearing loss (years) Duration of CI use (years) Etiology Implant type Default channel stimulation rate (pps)
C1 71 25 6 Unknown HiRes90K 5156b
C2 81 35 5 Unknown HiRes90K 1657c
C3 34 0 6 Atypical Meniere’s HiRes90K 5156d
C4 49 0 30 Genetic HiRes90K 5156
C5 (L) 48 7 8 Hereditary HiRes90K 5156d
C5 (R) 48 7 17 Hereditary HiRes90K 5156d

aDuration of severe to profound hearing loss is based on subjects’ self-report of the number of years they were unable to understand people on the telephone prior to implantation

bFor the dropped map with the dead region size of 14 electrodes, a channel stimulation rate of 2900 pulses per second (pps) was used

cFor the dropped map with the dead region size of 14 electrodes, a channel stimulation rate of 4972 pps was used. For the map with full 16 channels (i.e., no-dead region), a channel stimulation rate of 4094 pps was used

dFor the dropped map with the dead region size of 14 electrodes, a channel stimulation rate of 2900 pps was used