Skip to main content
. Author manuscript; available in PMC: 2016 Apr 1.
Published in final edited form as: Steroids. 2015 Jan 29;96:140–152. doi: 10.1016/j.steroids.2015.01.014

Table 5.

Accuracy and precision for determination of estrogens as NMPS derivatives in serum (n=5).

Analyte LQC (1.5 pg/mL) MQC (75 pg/mL) HQC (175 pg/mL)

Mean SD CV Accuracy Mean SD CV Accuracy Mean SD CV Accuracy
Intra-day

E2 1.5 0.2 10% 102% 80.7 1.7 2% 108% 183.8 3.0 2% 105%
16α-OH-E2 1.8 0.1 5% 118% 79.2 1.1 1% 106% 180.2 2.7 2% 103%
4-MeO-E2 1.6 0.2 14% 105% 77.9 1.6 2% 104% 176.5 8.0 5% 101%
2-MeO-E2 1.7 0.2 9% 112% 76.0 0.7 1% 101% 179.3 2.5 1% 102%
4-OH-E2 1.5 0.1 6% 102% 80.2 1.3 2% 107% 180.6 1.0 1% 103%
2-OH-E2 1.6 0.1 6% 107% 71.5 2.4 3% 95% 171.4 5.1 3% 98%

Inter-day

E2 1.4 0.1 4% 91% 78.5 0.9 1% 105% 173.2 9.0 5% 99%
16α-OH-E2 1.5 0.2 11% 102% 79.0 1.8 2% 105% 174.1 8.1 5% 99%
4-MeO-E2 1.6 0.2 11% 105% 83.2 3.7 4% 111% 185.7 10.8 6% 106%
2-MeO-E2 1.9 0.1 5% 124% 79.0 2.2 3% 105% 173.7 7.6 4% 99%
4-OH-E2 1.6 0.1 8% 104% 77.5 2.4 3% 103% 172.4 7.3 4% 99%
2-OH-E2 1.4 0.3 20% 95% 76.3 1.5 2% 102% 166.0 8.1 5% 95%

SD: standard deviation

CV: coefficient of variation

RE: relative error

RE (%) = (found concentration – actual concentration/actual concentration)×100

Accuracy (%) = RE (%) + 100