Skip to main content
. Author manuscript; available in PMC: 2015 Mar 25.
Published in final edited form as: JACC Cardiovasc Imaging. 2014 May;7(5):453–461. doi: 10.1016/j.jcmg.2014.01.013

Table 4.

Parameters of LA Assessment According to the Presence of ECE in MS Patients in Sinus Rhythm and in Controls

Patients
Without Events
(n = 139)
Patients
With Events
(n = 27)
p Value Reference
Controls*
(n = 20)
LA anteroposterior diameter, mm 48.7 ± 5.7 49.4 ± 6.8 0.773 32.9 ± 4.6
3D LA volume, ml/m2 49.6 ± 13.2 54.2 ± 20.8 0.294 17.1 ± 4.5
3D LA CSA, cm2/m2 12.3 ± 2.5 14.2 ± 4.5 0.002 6.9 ± 2.1
3D LAEF, % 32.6 ± 15.2 24.9 ± 17.2 0.031 58.6 ± 6.2
3D LA shape index 1.59 ± 0.41 1.28 ± 0.36 <0.001 1.73 ± 0.37

Values are mean ± SD.

*

p < 0.05 for patients versus control subjects.

Abbreviations as in Table 1.