Skip to main content
. 2015 Mar 25;10(3):e0121067. doi: 10.1371/journal.pone.0121067

Table 1. Change (Δ) in Mean Power with Respect to Baseline.

DBS Set (number of sides) Alpha (8–12 Hz) Beta (13–35 Hz)
130 Hz/2V Δ = -0.265 Δ = -0.431
(N = 14) ↓ P < 0.001 ↓ P < 0.001
130 Hz/1.35V Δ = -0.0685 Δ = -0.155
(N = 14) ↓ P = 1 ↓ P = 0.193
60 Hz/2V Δ = + 0.182 Δ = + 0.0932
(N = 14) ↑ P < 0.05 ↑ P = 1

The total power delivered during 60 Hz/2V DBS was equivalent to that delivered during 130 Hz/1.35V DBS. However, their effects on baseline spectral power were significantly different from each other in both the alpha (P < 0.001) and beta (P = 0.006) bands.