Table 2. Lower limits of detection of LAMP and PCR assays.
(A) Lower limit detection test of spiked samples with DNA extracted by QIAamp DNA minikit | |||||
Sample type | Trophozoites/reaction | ||||
104 | 103 | 102 | 10 | 1 | |
Spiked water | |||||
LAMP | +a | + | + | + | + |
PCR | + | + | + | + | + |
Spiked CSF | |||||
LAMP | + | + | + | + | + |
PCR | + | + | + | + | + |
(B) Lower limit detection test of spiked samples DNA extracted by heating method | |||||
Sample type | Trophozoites/reaction | ||||
104 | 103 | 102 | 10 | 1 | |
Spiked water | |||||
LAMP | + | + | + | + | ± (2/3) |
PCR | + | + | + | + | ± (1/3) |
Spiked CSF | |||||
LAMP | + | + | + | + | + |
PCR | + | + | + | + | ± (1/3) |
a +, triplicated assay showed all positive; ±, triplicated assay showed both positive and negative (positive number/test number);-, triplicated assay showed all negative.