Skip to main content
. 2015 Mar 30;10(3):e0120997. doi: 10.1371/journal.pone.0120997

Table 3. Categories of water samples tested in this study with number N. fowleri-positive by LAMP and PCR.

Location and type of water (No. of sample) Area characteristic LAMP positive/examined PCR positive/examined
Nakhon Pathom Province Suburban    
- Flood (80) 5/80 4/80
Nan Province Rural
- Rain (6) 1/6 0/6
- Surface (4) 1/4 1/4
- Ground (1) 1/1 0/1
- Stream (1) 0/1 0/1
Phayao Province Rural
- Surface (3) 1/3 1/3
Kanchanaburi Province Rural
- Rain (2) 0/2 0/2
- Ground (2) 0/2 0/2
Chantaburi Province Rural
- Rain (2) 0/2 0/2
- Tap (2) 1/2 1/2
- Ground (1) 1/1 1/1
Trat Province Rural
- Tap (1) 0/1 0/1
- Ground (1) 1/1 1/1
Trang Province Rural
- Rain (1) 0/1 0/1
- Surface (2) 1/2 1/2
- Ground (1) 0/1 0/1
Total (110)* 13/110 (11.8%) 10/110 (9%)

*P value for McNemar's test = 0.25