Skip to main content
. Author manuscript; available in PMC: 2016 Apr 1.
Published in final edited form as: Hear Res. 2014 Nov 6;322:163–170. doi: 10.1016/j.heares.2014.10.008

Table 1.

Analysis filter boundaries for the standard and gradual groups for each session. The “Shift” column indicates the amount of frequency mismatch between the analysis filters in this table and the synthesis filters in Table 2, expressed in mm of displacement along the cochlea.

Gradual Group Session numbers Standard Group Session numbers Shift (mm) Analysis filter frequency boundaries (Hz)
1 - 0 854 1467 2032 2732 3800 5150 6622 9568 11000
2 - 1 722 1257 1749 2358 3288 4464 5746 8312 11000
3 - 2 608 1073 1502 2032 2842 3866 4984 7218 11000
4 - 3 508 914 1287 1749 2454 3346 4319 6266 11000
5 - 4 421 774 1099 1502 2116 2893 3740 5435 9673
6 - 4.5 382 711 1015 1390 1964 2689 3480 5062 9016
7 - 5 345 653 936 1286 1822 2499 3237 4713 8404
8 - 5.5 311 598 862 1190 1684 2320 3009 4387 7831
9 - 6 279 547 794 1099 1565 2154 2798 4084 7298
10–15 1–15 6.5 250 500 730 1015 1450 2000 2600 3800 6800