Skip to main content
. 2015 Apr 1;6:100. doi: 10.3389/fphys.2015.00100

Table 1.

Short-term monitoring and AF detection.

Sources Intervention Duration of monitoring N AF Detected (%)
Bansil and Karim (Bansil and Karim, 2004) CCM NA 121 4.9
Barthelemy (Barthelemy et al., 2003) CCM 70 h 52 7.7
Gumbinger (Gumbinger et al., 2012) CCM 24 h 312 11.9
Kallmunzer (Kallmunzer et al., 2012) CCM 76 h 271 6.6
Lazzaro (Lazzaro et al., 2012) CCM 73 h 133 6.0
Rem (Rem et al., 1985) CCM 48 h 169 2.4
Rizos (Rizos et al., 2010) CCM 48 h 136 21.3
Rizos (Rizos et al., 2012) CCM 64 h 496 5.4
Ritter (Ritter et al., 2013) CCM 72 h 1110 1.3
Sulter (Sulter et al., 2003) CCM 48 h 27 18.5
Sutamnartpong (Sutamnartpong et al., 2014) CCM 24 h 204 5.8
Vivanco (Vivanco Hidalgo et al., 2009) CCM 55 h 465 7.1
Fudji (Fujii et al., 2013) CCM or Holter NA 113 11.5
Barthelemy (Barthelemy et al., 2003) Holter 24 h 55 5.5
Douen (Douen et al., 2008) Holter 24 h 126 9.5
Gladstone (Gladstone et al., 2014) Holter 24 h 277 3.2
Gumbinger (Gumbinger et al., 2012) Holter 24 h 192 1.0
Gunalp (Gunalp et al., 2006) Holter 24 h 26 42.3
Hornig (Hornig et al., 1996) Holter 24 h 261 3.8
Jabaudon (Jabaudon et al., 2004) Holter 24 h 139 5.0
Kessler (Kessler and Kessler, 1995) Holter 24 h 93 0.0
Lazzaro (Lazzaro et al., 2012) Holter 24 h 133 0.0
Rizos (Rizos et al., 2012) Holter 24 h 496 2.8
Ritter (Ritter et al., 2013) Holter 24 h 1110 0.5
Schaer (Schaer et al., 2004) Holter 24 h 425 2.1
Shafqat (Shafqat et al., 2004) Holter 24 h 210 2.4
Sobocinski (Doliwa Sobocinski et al., 2012) Holter 24 h 249 2.0
Stahrenberg (Stahrenberg et al., 2010) Holter 24 h 224 4.8
Tagawa (Tagawa et al., 2007) Holter 24 h 299 8.4
Thakkar (Thakkar and Bagarhatta, 2014) Holter 24 h 52 5.8
Rem (Rem et al., 1985) Holter 24–48 h 51 3.9
Dangayach (Dangayach et al., 2011) Holter 48 h 51 23.6
Stahrenberg (Stahrenberg et al., 2010) Holter 48 h 224 6.4
Schuchert (Schuchert et al., 1999) Holter 72 h 82 6.1
Stahrenberg (Stahrenberg et al., 2010) Holter 7 d 224 12.5
Ritter (Ritter et al., 2013) Holter 7 d 60 1.7

MCOT, mobile cardiac outpatient telemetry; ICM, implantable cardiac monitor; ELR, external loop recorder; NA, not available.