Skip to main content
. 2015 Apr 1;6:100. doi: 10.3389/fphys.2015.00100

Table 2.

Medium and long-term monitoring and AF detection.

Sources N AF Definition Intervention Duration of monitoring AF detected (%)
Barthelemy (Barthelemy et al., 2003) 28 30 s ELR 70 h 14.3
Jabaudon (Jabaudon et al., 2004) 88 “seconds” ELR 7 d 5.7
Wallman (Wallmann et al., 2007) 127 30 s ELR 7 d 14.2
Elijovich (Elijovich et al., 2009) 20 30 s ELR 30 d 20.0
Flint (Flint et al., 2012) 236 30 s ELR 30 d 7.0
Gaillard (Gaillard et al., 2010) 98 30 s TTM 30 d 9
Gladstone (Gladstone et al., 2014) 280 30 s ELR 30 d 16.1
2.5 min 9.9
Bhatt (Bhatt et al., 2011) 62 30 s MCOT 28 d 24
5 min 9
Kamel (Kamel et al., 2013) 20 30 s MCOT 21 d 0.0
Miller (Miller et al., 2013) 156 30 s MCOT 30 d 5
Tayal (Tayal et al., 2008) 56 30 s MCOT 21 d 5
Christensen (Christensen et al., 2014) 85 2 min ICM 19 m 16.1
Cotter (Cotter et al., 2013) 51 2 min ICM 7.6 m 25.5
Dion (Dion et al., 2010) 24 30 s ICM 14.5 m 0.0
Etgen (Etgen et al., 2013) 22 6 min ICM 12 m 27.3
Ritter (Ritter et al., 2013) 60 2 min ICM 12.8 m 16.7
Rojo-Martinez (Rojo-Martinez et al., 2013) 101 2 min ICM 9.4 m 33.7
Sanna (Sanna et al., 2014) 221 2 min ICM 6 m 8.9

MCOT, mobile cardiac outpatient telemetry; ICM, implantable cardiac monitor; ELR, external loop recorder.