Skip to main content
. 2015 Mar 30;68(2):116–121. doi: 10.4097/kjae.2015.68.2.116

Table 6. Attempts of Endotracheal Intubation according to the Height of the Operating Table.

Height of the operating table Attempts of endotracheal intubation Group S (n = 97) Group R (n = 96)
Umbilicus First 7 (7.2) 10 (10.4)
Second 12 (12.4) 19 (19.8)
Need for an alternative technique or additional operator 27 (27.8) 16 (16.7)*
Successful endotracheal intubation 19 (19.6) 29 (31.2)*
Failed endotracheal intubation 27 (27.8) 16 (16.7)*
Xiphoid First 9 (9.3) 12 (12.5)
Second 14 (14.4) 22 (22.9)
Need for an alternative technique or additional operator 28 (28.9) 17 (17.7)*
Successful endotracheal intubation 23 (23.7) 34 (35.4)*
Failed endotracheal intubation 28 (28.9) 17 (17.7)*

Values are expressed as number of patients (%). Group S: sniffing position, Group R: ramped position. *P < 0.05 vs group S. Successful endotracheal intubation is defined as success at the first or second attempt.