Skip to main content
. 2015 Mar 23;2015:845643. doi: 10.1155/2015/845643

Table 1.

Effect of differing lighting conditions and pharmacologic dilation on pupil size and angle metrics obtained with Cirrus. Results are presented as mean ± standard deviation.

Light Dark Pharmacologic dilation P value
Pupil size (mm) 4.00 ± 0.81 5.27 ± 0.77 6.54 ± 0.76 overall: <0.0011
(1)-(2): <0.0012
(1)–(3): <0.0012
(2)-(3): <0.0012

SL-AOD (mm) 0.87 ± 0.31 0.75 ± 0.29 0.9 ± 0.38 overall: <0.0011
(1)-(2): <0.0012
(1)–(3): 0.0012
(2)-(3): <0.0012

SL-TISA (mm2) 0.33 ± 0.14 0.29 ± 0.13 0.34 ± 0.17 overall: 0.0031
(1)-(2): <0.0012
(1)–(3): 0.0572
(2)-(3): <0.0012

1Repeated measures, ANOVA.

2Post hoc pairwise comparisons.

SL-AOD: Schwalbe's line-angle opening distance.

SL-TISA: Schwalbe's line-trabecular-iris space area.