Skip to main content
. 2015 Jan;104(1):45–52. doi: 10.5935/abc.20140167

Table 2.

Follow-up, procedures performed, clinical and echocardiographic outcomes of the patients of this study

    Follow-up: 20.3 ± 17 months  
    Number of procedures  
    23 (74.2%) 1 procedure
Ablations 31 6 (19.3%) 2 procedures
    2 (6.4%) 3 procedures
    Maintenance of sinus rhythm  
Sinus rhythm 24 (77%)    
    4 clinical control  
AF 7 (23%) 3 tachycardiomyopathy → PM - good outcome
  Clinical and echocardiographic findings  
  Pre-ablation Post-ablation p
NYHA 2.23 ± 0. 1.13 ± 0.35 < 0.0001
EF 44.68% ± 6 59% ± 13.2% p = 0.0005
LA 46.61 ± 7.3 43.59 ± 6.6 mm p = 0.026

AF: atrial fibrillation; PM: pacemaker; NYHA: New York Heart Association; EF: ejection fraction; LA: left atrium.