Skip to main content
. 2015 Mar 27;71(Pt 4):969–985. doi: 10.1107/S1399004715002485

Table 2. SAXS data collection and derived parameters for 4 FnIII-3,4.

Data-collection parameters
Instrument EMBL P12 beamline, PETRA, DESY, Hamburg
Beam geometry 0.2 0.12mm
Wavelength () 1.24
q range (1) 0.010.35
Exposure time (s) 20 0.05
Concentration range (mgml1) 1.548.6
Temperature (K) 283
Structural parameters
I(0)/c (102cm2mg1) (from Guinier) 1.24 0.01
R g () (from Guinier) 22.1 0.8
I(0) (102cm2mg1) [from P(r)] 1.23 0.01
R g () [from P(r)] 22.0
D max () 70
Porod volume estimate V p (3) 32000 1000
Excluded volume estimate V ex (3) 42000 200
Molecular-mass determination
I(0) (102cm2mg1) 4.20 0.01
Molecular mass M r (Da) [from I(0)] 19200
Molecular mass M r (Da) [from (V p/1.6)] 20000 625
Molecular mass M r (Da) [from (V ex/2)] 21000 100
Calculated monomeric M r from sequence 23360
Software used
Primary data reduction Automated SAXS pipeline
Data processing PRIMUS (Konarev et al., 2003)
Ab initio analysis DAMMIF (Franke Svergun, 2009), DALAI_GA (Chacn et al., 2000)
Validation and averaging SUPCOMB (Kozin Svergun, 2001) DAMAVER (Volkov Svergun, 2003)
Computation of model intensities CRYSOL (Svergun et al., 1995)
Three-dimensional graphical representations PyMOL (Schrdinger)
SASBDB code SASDAT6

Values reported for the data extrapolated to infinite dilution.

Absolute intensities determined using water as a secondary standard (Orthaber et al., 2000).

§

Calculated using BSA as a standard (66000Da).