Skip to main content
. 2015 Mar 26;13:26. doi: 10.1186/s40201-015-0175-1

Table 3.

effect of vertical anoxicaerobic continuous flow combined bioreactor and control reactor on naphthalene and COD concentration and their removal efficiency

Naphthalene concentration Naphthalene removal efficiency COD
Anoxic/Oxic reactor Control reactor
0.5 mg/l (%) 66 27 78
mg/l 0.17 ± 0.6 0.365 ± 0.01 0.11 ± 4.2
1 mg/l (%) 58.4 21.5 94
mg/l 0.416 ± 0.02 0.785 ± 0.05 0.06 ± 0.03
5 mg/l (%) 51 26.5 90
mg/l 2.45 ± 1.5 3.675 ± 0.21 0.5 ± 0.6
10 mg/l (%) 44.5 19.5 92
mg/l 5.55 ± 0.5 8.05 ± 2.15 0.8 ± 0.05
20 mg/l (%) 32.5 17 89
mg/l 13.5 ± 4.50 16.6 ± 5.48 2.2 ± 1.35