Skip to main content
. 2015 Apr 8;9:181. doi: 10.3389/fnhum.2015.00181

Table 2.

Specificity (%) of the spindle detection algorithms across the eight EEG signals (higher values indicate better performance).

Signal1 Signal2 Signal3 Signal4 Signal5 Signal6 Signal7 Signal8 Mean ± std
a1 85 79.8 83.9 82.9 82.6 85.2 80.7 79.1 82.4±2.3
a2 99.6 100 99.6 98.8 99.2 99.4 98.9 99.1 99.3±0.4
a3 91.1 97.6 75.1 92.7 88.5 77.8 89.1 39 81.4±18.7
a4 98.5 98.3 97 96.5 98.2 98.6 95.6 94.3 97.1±1.6
a5 99.8 99.2 96.1 96.3 99.6 98.8 97.1 96.1 97.9±1.6
a6 86.6 67 87 87.1 91.1 92.5 82 79.5 84.1±8.1
a7 94.6 93.4 94.5 87.3 95.5 97.3 94.1 78.1 91.8±6.3
a8 78.6 76.3 77.8 68.1 80.9 86.6 75.5 55.7 74.9±9.4

The best performing algorithm for each case appears in bold.