Skip to main content
. 2015 Apr 14;9:56. doi: 10.3389/fnsys.2015.00056

Table 2.

Diffusion Tensor Imaging results for white selected white matter tracts in the Eyeborg user and controls.

FA value ADC value (10−3MM2/S)
Corpus callosum Eyeborg user 0.57 ± 0.02* 0.92 ± 0.03
Controls 0.52 ± 0.03 0.88 ± 0.02
Inferior longitudinal fasciculus
Left Eyeborg user 0.53 ± 0.01 0.85 ± 0.02
Controls 0.49 ± 0.03 0.84 ± 0.04
Right Eyeborg user 0.51 ± 0.01 0.86 ± 0.02
Controls 0.48 ± 0.02 0.82 ± 0.04
Inferior fronto-occipital fasciculus
Left Eyeborg user 0.51 ± 0.06 0.82 ± 0.02
Controls 0.45 ± 0.08 0.85 ± 0.09
Right Eyeborg user 0.50 ± 0.07 0.83 ± 0.01
Controls 0.48 ± 0.01 0.89 ± 0.02

FA = fractional anisotropy value; ADC = apparent diffusion coefficient; *p < 0.05. Diffusion Tensor Imaging results for white selected white matter tracts in the Eyeborg user and controls.