Skip to main content
. 2015 Feb;65(1):54–61.

Table 2.

Calculated measurements (mean ± SEM) of hemodynamics

Isoflurane α-Chloralose P
Baseline
 Cardiac output (L/min) 2.07 ± 0.13 1.66 ± 0.06a <0.004
 Systemic vascular resistance (dyn × s/cm5) 2348 ± 162 3690 ± 158a <0.004
 Pulmonary vascular resistance (dyn × s/cm5) 185 ± 43 450 ± 101 0.078
 RV:LV ratio 0.80 ± 0.26 0.83 ± 0.03 0.843
Clot induction
 Cardiac output (L/min) 1.70 ± 0.09 1.49 ± 0.04 0.020
 Systemic vascular resistance (dyn × s/cm5) 2366 ± 204 3256 ± 160a <0.004
 Pulmonary vascular resistance (dyn × s/cm5) 907 ± 58 1617 ± 192 0.020
 RV:LV ratio 1.32 ± 0.25 1.23 ± 0.07 0.669
Treatment
 Cardiac output (L/min) 1.48 ± 0.09 1.75 ± 0.09 0.030
 Systemic vascular resistance (dyn × s/cm5) 2334 ± 263 3096 ± 123 0.008
 Pulmonary vascular resistance (dyn × s/cm5) 954 ± 160 1184 ± 133 0.305
 RV:LV ratio 1.12 ± 0.14 1.02 ± 0.02 0.393
a

Value significantly different from that for isoflurane group.