Skip to main content
. 2014 Apr 27;52(5):2634–2645. doi: 10.1007/s13197-014-1378-7

Table 1.

Coded levels for independent variables used in developing experimental data

Code Level
Factor -α (−1.68) −1 0 1 α (1.68)
Feed Moisture (%) X1 14.98 16 17.5 19 20.02
Die Temperature (°C) X2 104.77 115 130 145 155.23
Screw Speed (rpm) X3 11.91 150 200 250 284.09