Table 2. Results of statistical analyses on the modeling of moisture ratio and drying time.
Model | Voltage | n | k | a | b | c | E RMS | χ 2 | EF |
---|---|---|---|---|---|---|---|---|---|
Lewis | 10kV | 0.1169 | 0.083224 | 0.007157 | 0.928333 | ||||
15kV | 0.1287 | 0.067934 | 0.004769 | 0.950555 | |||||
20kV | 0.1398 | 0.063217 | 0.004130 | 0.957811 | |||||
25kV | 0.1493 | 0.057563 | 0.003424 | 0.964794 | |||||
30kV | 0.1635 | 0.055645 | 0.003200 | 0.967720 | |||||
Page | 10kV | 1.6568 | 0.0294 | 0.009922 | 0.000102 | 0.998981 | |||
15kV | 1.5009 | 0.0459 | 0.010705 | 0.000118 | 0.998772 | ||||
20kV | 1.4523 | 0.0562 | 0.010911 | 0.000123 | 0.998743 | ||||
25kV | 1.4003 | 0.0676 | 0.012061 | 0.000150 | 0.998454 | ||||
30kV | 1.3791 | 0.0788 | 0.014127 | 0.000206 | 0.997919 | ||||
Henderson and Pabis | 10kV | 0.1355 | 1.1417 | 0.064598 | 0.004312 | 0.956822 | |||
15kV | 0.1451 | 1.1180 | 0.053012 | 0.002904 | 0.969890 | ||||
20kV | 0.1563 | 1.1129 | 0.049214 | 0.002503 | 0.974431 | ||||
25kV | 0.1649 | 1.1024 | 0.045475 | 0.002137 | 0.978027 | ||||
30kV | 0.1795 | 1.0985 | 0.044798 | 0.002074 | 0.979078 | ||||
Logarithmic | 10kV | 0.0408 | 2.2771 | -1.2205 | 0.021721 | 0.000488 | 0.995118 | ||
15kV | 0.0646 | 1.6579 | -0.6119 | 0.017195 | 0.000306 | 0.996832 | |||
20kV | 0.0816 | 1.4739 | -0.4275 | 0.016005 | 0.000265 | 0.997296 | |||
25kV | 0.0948 | 1.3715 | -0.3307 | 0.014127 | 0.000206 | 0.997880 | |||
30kV | 0.1103 | 1.3043 | -0.2654 | 0.013466 | 0.000187 | 0.998110 | |||
Quadratic | 10kV | 1.0579 | -0.0921 | 0.0015 | 0.020337 | 0.000427 | 0.995721 | ||
15kV | 1.0437 | -0.1024 | 0.0023 | 0.013988 | 0.000202 | 0.997904 | |||
20kV | 1.0401 | -0.1114 | 0.0029 | 0.011234 | 0.000130 | 0.998668 | |||
25kV | 1.0301 | -0.1171 | 0.0033 | 0.008224 | 0.000070 | 0.999281 | |||
30kV | 1.0227 | -0.1252 | 0.0038 | 0.006635 | 0.000045 | 0.999541 |