Skip to main content
. Author manuscript; available in PMC: 2016 Jun 1.
Published in final edited form as: Ann Biomed Eng. 2014 Oct 15;43(6):1321–1334. doi: 10.1007/s10439-014-1149-7

Table 2.

Diameter, angle and offset location for the Original configuration and all surgical variations for the Y-graft baffles generated. The letters in italics correspond to those in Figure 2 (A.1 and A.2) and refer to specific parametric variations; n: original angle location; e: original offset location; 0.5D: offset distance of half a diameter from original value.

Surgical
variation
Diameter
(D)
Branch 1 Branch 2

Angle
(degrees)
Offset (mm) Angle
(degrees)
Offset (mm)

Original 18-9-9
or 20-
10-10
n e n e
1 +2mm n e n e
2 −2mm n e n e
3 - n 0.5D top left (i) n e
4 - n 0.5D top right (g) n e
5 - n 0.5D bottom left (c) n e
6 - n 0.5D bottom right (a) n e
7 - n e n 0.5D top left (i)
8 - n e n 0.5D top right (g)
9 - n e n 0.5D bottom left (c)
10 - n e n 0.5D bottom right (a)
11 - 33° top left (j) e n e
12 - 33° top right (l) e n e
13 - 33° bottom left (p) e n e
14 - 33° bottom right (r) e n e
15 - n e 33° top left (j) e
16 - n e 33° top right (l) e
17 - n e 33° bottom left (p) e
18 - n e 33° bottom right (r) e