Skip to main content
. Author manuscript; available in PMC: 2015 Nov 1.
Published in final edited form as: Pract Radiat Oncol. 2014 Aug 12;4(6):e259–e268. doi: 10.1016/j.prro.2014.06.010

Table 1.

Tumor location, size, motion, and the prescribed dose

Patient
no.
Tumor
location
Tumor
volume (cc)
Tumor
motion (mm)
Prescribed dose
fxs × Gy/fx
1 RM 472.2 16.6 35 × 2
2 RL 545.1 10.0 35 × 2
3 RU 236.8 8.5 35 × 2
4 LM 358.2 4.6 35 × 2
5 LM 40.8 4.3 35 × 2
6 LM 20.6 2.1 35 × 2
7 RM 26.2 1.4 35 × 2

R, right; L, left; U, upper; L, lower; M, middle; fx, fraction