Skip to main content
. 2013 Jul;17(3):285–290. doi: 10.7162/S1809-97772013000300009

Table 4. Audiological outcomes and speech perception among children with a cochlear implant.

ID Effective use of CI Time of CI use PTA (em dBNA) Category IT-MAIS/MAIS MUSS
Pre CI Pos CI Pre CI Pos CI Pre CI Pos CI Pre CI Pos CI
1. MLFN Yes 174 110 25 0 5 25% 100% 20% 100%
2. JLCS Yes 60 105 20 0 6 0% 100% 40% 97.5%
3. GAS Yes 54 105 25 0 6 7.5% 100% 45% 100%
4. MSLG No 48 100 60 0 1 30% 17.5% 25% 2.5%
5. ASLG No 36 70 50 0 2 55% 70% 80% 85%
6. AMNCT No 24 75 50 0 1 0% 60% 0% 75%
7. ACAFD No 6 ABS 110 0 0 10% 30% 40% 37%
8. VMM YES 24 75 30 0 4 5% 75% 20% 80%
9. ERM YES 6 ABS NR 0 1 0% 20% 0% 15%

CI: cochlear implant; PTA (Pure tone average) Average threshold at 500 Hz and 4000 Hz (11); ABS = Absent; NR=unrealized; Category: Category of speech perception (15).