Table 4. Audiological outcomes and speech perception among children with a cochlear implant.
ID | Effective use of CI | Time of CI use | PTA (em dBNA) | Category | IT-MAIS/MAIS | MUSS | ||||
---|---|---|---|---|---|---|---|---|---|---|
Pre CI | Pos CI | Pre CI | Pos CI | Pre CI | Pos CI | Pre CI | Pos CI | |||
1. MLFN | Yes | 174 | 110 | 25 | 0 | 5 | 25% | 100% | 20% | 100% |
2. JLCS | Yes | 60 | 105 | 20 | 0 | 6 | 0% | 100% | 40% | 97.5% |
3. GAS | Yes | 54 | 105 | 25 | 0 | 6 | 7.5% | 100% | 45% | 100% |
4. MSLG | No | 48 | 100 | 60 | 0 | 1 | 30% | 17.5% | 25% | 2.5% |
5. ASLG | No | 36 | 70 | 50 | 0 | 2 | 55% | 70% | 80% | 85% |
6. AMNCT | No | 24 | 75 | 50 | 0 | 1 | 0% | 60% | 0% | 75% |
7. ACAFD | No | 6 | ABS | 110 | 0 | 0 | 10% | 30% | 40% | 37% |
8. VMM | YES | 24 | 75 | 30 | 0 | 4 | 5% | 75% | 20% | 80% |
9. ERM | YES | 6 | ABS | NR | 0 | 1 | 0% | 20% | 0% | 15% |
CI: cochlear implant; PTA (Pure tone average) Average threshold at 500 Hz and 4000 Hz (11); ABS = Absent; NR=unrealized; Category: Category of speech perception (15).