Skip to main content
. Author manuscript; available in PMC: 2016 Jul 1.
Published in final edited form as: J Magn Reson Imaging. 2014 Oct 18;42(1):136–144. doi: 10.1002/jmri.24773

TABLE 1.

MRI parameters means in control and 2.5-h trypsin degraded BNC samples

MRI
Measurement
Control
(n = 60)
2.5-h Trypsin
(n = 60)
Coefficient of
Variation (%)
ADC (× 10−3 mm2/s) 1.90 ± 0.10 2.08 ± 0.09 ** 2.8
DW (b = 333 s/mm2) 1.12 ± 0.11 1.01 ± 0.06 ** 2.3
DW (b = 666 s/mm2) 1.79 ± 0.20 1.52 ± 0.11 ** 4.6
DW (b = 1000 s/mm2) 2.60 ± 0.41 2.39 ± 0.36 ** 12.5
DW (b = 1333 s/mm2) 1.89 ± 0.61 1.85 ± 0.55 6.3
DW (b = 1666 s/mm2) 1.14 ± 0.20 1.17 ± 0.17 13.5
DW (b = 2000 s/mm2) 0.97 ± 0.13 1.09 ± 0.14 ** 14.2
MTR 0.46 ± 0.02 0.43 ± 0.02 ** 1.7
MTW (Tsat = 50 ms) 0.69 ± 0.04 0.69 ± 0.03 1.5
MTW (Tsat = 100 ms) 0.68 ± 0.04 0.69 ± 0.03 2.0
MTW (Tsat = 150 ms) 0.58 ± 0.06 0.60 ± 0.03 ** 1.5
MTW (Tsat = 200 ms) 0.53 ± 0.03 0.54 ± 0.03 * 1.4
T1 (ms) 866.8 ± 31.4 1000.7 ± 31.7 ** 2.9
T1W 1.31 ± 0.15 1.32 ± 0.09 7.2
T2 - 3D (ms) 78.5 ± 6.3 88.3 ± 7.9 ** 2.5
T2 - 2D (ms) 50.2 ± 6.1 63.7 ± 9.9 ** 9.0
PDW (TE = 10 ms) 1.20 ± 0.13 1.16 ± 0.11 ** 0.9
IDW (TE = 30 ms) 0.97 ± 0.11 0.97 ± 0.09 0.9
T2W (TE = 60 ms) 0.72 ± 0.09 0.75 ± 0.08 ** 0.7
T2* (ms) 21 ± 7 25 ± 6 ** 5.7
*

p < 0.05 control vs. 2.5-h trypsin,

**

p < 0.01 control vs. 2.5-h trypsin