Comparison of some electroanalytical methods of determination of AA.

Type of electrode Pharmaceutical sample Linear range / μ M LOD / μ M Reference
CoHCF Tablet 55.2-32300 33.3 (43)
PtAu film Injection solution, tablet 103-1650 103 (44)
Carbon-nanofiber - 2.0-64 2.0 (45)
Poly (vinyl alcohol) - 10.0-250 7.6 (46)
Tin hexacyanoferrate - 400-50000 - (47)
Mesoporous carbon/Nafion 40-800 0.5 (48)
Oxidized glassy carbon electrode - 197-988 - (49)
Silver hexacyanoferrate nanoparticles - 4.0-78 0.42 (50)
Nickel hexacyanoferrate-modified Al Tablet, ampoule, syrup 2-200 2 (51)
Multi-walled carbon nanotubes-chitosan Tablet 1-400 0.8 (52)
Co(II) phthalocyanine-multi-walled carbon nanotubes - 10-2600 1.0 (53)
Single-walled carbon nanotube-modified carbon-ceramic Tablet 5.0-700.0 3.0 (54)
Pyrolytic graphite electrodes modified in dopamine solution - 25-500 13 (55)
Graphene oxide-CoHCF nanocomposite Tablet, ampoule, sachet 2.5-62.5 0.29 (This work)