Membrane distillation bioreactor operational parameters

Operational parameters Values
Feed side
 Reactor temperature, Tr (°C) 55·5
 Cross-sectional area (m2) 0·8 × 10−3
 Dissolved oxygen (DO, mg l−1) 3–4
 Airflow rate (L min−1) 12
Permeate side
 Permeate temperature, Tp,in (°C) 19·5
 Cross-sectional area (m2) 1·68 × 10−3