Table 1. Distribution of microbial counts (cfu/m3) of air samples collected from 30 studied ambulance runs 
(measurements were taken at the start of the run and during patient services).

Parameters Start of run
Number (%) of microbial counts
(cfu/m3) in each run
n=53
During patient services
Number (%) of microbial counts
(cfu/m3) in each run
n=106
Number (%) of microbial counts (cfu/m3) in outdoor air
n=60
≤300 301-500 >500 ≤300 301-500 >500 Before run
>1000
After run
>1000
Bacterial counts
Mean±SD
23(76.6) 2(6.7) 5(16.7) 19(63.3) 4(13.4) 7(23.3) 4(13.3) 4(13.3)
318±485* 468±607* 537±577 518±589
Fungal counts
Mean+SD
16(53.3) 4(13.4) 10(33.3) 11(36.6) 5(16.7) 14(46.7) 10(33.3) 12(40.0)
522±581** 656±612** 1191±908 1221±997

* Statistically significant difference by t-test, p=0.005

** Statistically significant difference by t-test, p=0.030

Remarks: One to two air samples per ambulance run were collected at the start of runs, and three to four were collected during patient services. Two air samples per ambulance run were collected from outdoor air (one before the ambulance run and one after).