Skip to main content
. Author manuscript; available in PMC: 2016 May 30.
Published in final edited form as: J Comput Chem. 2015 Mar 31;36(14):1083–1101. doi: 10.1002/jcc.23897

Table 1.

Parameters for fitted N-ethylsulfamate (NESM; compound 9 in figure 1) compared to the initial guess (see section 4.2.1). RMSE values were calculated as in reference 12 but without weighting.

Parameter definition “Blind”a fit; RMSE = 0.36 kcal/mol “Targeted”a fit; RMSE = 0.27 kcal/mol “Adapted”a fit; RMSE = 0.27 kcal/mol Initial guess; RMSE = 0.99 kcal/mol

BOND

Atom types Force constantb Reference lengthb Force constantb Reference lengthb Force constantb Reference lengthb Force constantb Reference lengthb

CG321 NG2S3 318.7 1.443 322.4 1.443 329.2 1.444 266.0 1.460

ANGLES

Atom types Force constantb Reference angleb Force constantb Reference angleb Force constantb Reference angleb Force constantb Reference angleb

CG331 CG321 NG2S3 23.0 108.4 27.3 109.7 37.7 111.6 70.0 109.5
NG2S3 CG321 HGA2 38.0 105.2 38.3 105.2 38.7 105.2 51.5 107.5
CG321 NG2S3 SG3O1 76.5 107.9 58.7 104.9 54.2 104.0 39.5 103.1
CG321 NG2S3 HGP1 51.5 109.5 51.8 109.5 52.2 109.5 35.0 109.0

DIHEDRALS

Atom types Multiplicity Amplitudeb Phaseb Amplitudeb Phaseb Amplitudeb Phaseb Amplitudeb Phaseb

CG331 CG321 NG2S3 SG3O1 1 0.453 180 0.755 180 0.653 180 1.500 180
CG331 CG321 NG2S3 SG3O1 2 1.137 0 0.866 0 0.885 0 0.650 180
CG331 CG321 NG2S3 SG3O1 3 0.391 0 0.628 0 0.667 0 1.000 0
CG331 CG321 NG2S3 SG3O1 4 0.190 180 0.151 180 0.142 180 N/A N/A
CG331 CG321 NG2S3 SG3O1 6 0.107 0 0.113 0 0.111 0 N/A N/A

CG331 CG321 NG2S3 HGP1 1 1.110 0 0.741 0 0.790 0 0.000 0
CG331 CG321 NG2S3 HGP1 2 0.477 0 0.321 0 0.325 0 N/A N/A
CG331 CG321 NG2S3 HGP1 3 0.052 180 0.235 180 0.266 180 N/A N/A

CG321 NG2S3 SG3O1 OG2P1 3 0.545 0 0.552 0 0.556 0 0.537 0
a

In the blind fit, bonds and angles are unrestrained, while in the targeted fit, they are restrained towards their initial guess values, as discussed in section 2.10. Dihedrals are restrained towards 0 in all cases. Both the blind and targeted fit were obtained using the uniform bias; conversely, the adapted fit is the same as the targeted fit but using the target-adapted bias.

b

Conform CHARMM conventions, bond force constants are in kcal mol−1 Å−2, bond reference lengths in Å, angle force constants in kcal mol−1 radian−2, reference angles and dihedral phases in degrees, and dihedral amplitudes in kcal mol−1.