Table 3. Lung mechanical properties measured during different ZTs in WT mice exposed to chronic air and CS infected with influenza A virus.

Sl. No. ZT time (Hrs) Lung Compliance (mL/cmH2O) Lung Resistance (cmH2O.s/mL) Tissue Elastance (cmH2O/mL)
Air+Virus CS+Virus Air+Virus CS+Virus Air+Virus CS+Virus
1. ZT6 0.038 ± 0.003 0.052 ± 0.003 $ 0.849 ± 0.018 0.683 ± 0.042 26.943 ± 1.775 19.587 ± 1.390
2. ZT12 0.054 ± 0.002 0.041 ± 0.007 **, 0.673 ± 0.032 0.972 ± 0.181*, 18.704 ± 0.643 27.801 ± 6.493*
3. ZT18 0.047 ± 0.003 0.036 ± 0.012**, †† 0.748 ± 0.016 1.171 ± 0.365*, §, †† 21.464 ± 1.259 32.189 ± 11.074 §, †
4. ZT24 0.048 ± 0.001 0.035 ± 0.004 **, †† 0.809 ± 0.016 0.783 ± 0.078 # 21.022 ± 0.337 28.697 ± 3.123

Data are shown as mean ± SEM (n = 2–4 per group). **P < 0.01, significant compared to Air+Virus (ZT12); $ P < 0.05, significant compared to Air+Virus (ZT6); *P < 0.05, significant compared to Air+Virus (ZT12, and ZT18); § P < 0.05, significant compared to Air+Virus (ZT12 and ZT24); P < 0.05, and †† P < 0.01, significant compared to CS+Virus (ZT6); # P < 0.05, significant compared to CS+Virus (ZT18).