Skip to main content
. 2015 Apr;7(4):697–703. doi: 10.3978/j.issn.2072-1439.2015.04.31

Table 3. Diagnostic performances of bronchoscopic sampling techniques.

Sampling technique Diagnostic yield (%)
Overall Size
Etiology
Probe location
<20 mm (n=45) >20 mm (n=67) P value Benign (n=36) Malignancy (n=76) P value Within (n=92) Adjacent (n=18) P value
TBB 70.5 62.2 76.1 0.110 63.9 73.7 0.290 76.1 50 0.02
Brushing cell block 34.8 22.2 43.3 0.020 19.4 42.1 0.020 40.2 11.1 0.018
Brushing smear 62.5 55.6 67.2 0.210 27.8 78.9 <0.001 69.6 33.3 0.003
Rinsed brushing fluid 50 37.8 58.2 0.030 11.1 68.4 <0.001 57.6 16.7 0.001
BALF 42 28.9 50.7 0.020 13.9 55.3 <0.001 47.8 16.7 0.015
All techniques 80.4 75.6 83.6 0.290 69.4 85.5 0.045 87 55.6 0.002

TBB, transbronchial biopsy; BALF, bronchoalveolar lavage fluid.