Table 2. Results of the indexing tests (360 frames per data collection).
| Sample | Average No. of reflections per crystal | Method | No. of patterns indexed | No. of correct solutions | Time† (per frame) |
|---|---|---|---|---|---|
| Sanidine | 11 | laue | 332 | 285‡ | 1min |
| mono1 | 105 | 105 | 4 s | ||
| mono2 | 359 | 359 | 40 s | ||
| Cs2[Pt(CN)4]H2O | 15 | laue | 360 | 357‡ | 1min |
| mono1 | 205 | 203 | 5 s | ||
| mono2 | 360 | 360 | 12 s | ||
| ZSM-5§ 1 crystal | 44 | laue | 360 | 347 | 110min |
| mono1 | 353 | 343 | 0.5 s | ||
| mono2 | 360 | 351 | 12 s | ||
| ZSM-5§ 3 crystals | 23 | laue | 835 | 791 | 1030min |
| mono1 | 964 | 826 | 22 s | ||
| mono2 | 1004 | 902 | 12 s | ||
| ZSM-5§ 15 crystals | 57 | mono1 | 2190 | 1965 | 55 s |
| mono2 | 3027 | 2854 | 30 s |
Indexing trials were performed on a single core of a 2010 Mac Pro equipped with a dual 2.4GHz Quad-Core Intel Xeon processor.
Solutions with less than 6 indexed peaks were discarded.
Incorrect solutions for ZSM-5 correspond to a/b flipping.