Skip to main content
. 2015 Feb 11;308(9):C729–C736. doi: 10.1152/ajpcell.00399.2014

Table 1.

Changes in the peak current amplitudes and rates in receptor desensitization during repetitive agonist application

ATP Applications, 100 μM
Parameters 1st 2nd 3rd 4th
τdes, s 13.4 ± 3.4 (7) 7.3 ± 1.7 (7) 5.2 ± 0.4 (6) 3.3 ± 0.6 (4)
Imax, pA/pF 274 ± 25 (7) 215 ± 32 (7) 204 ± 37 (6) 193 ± 42 (4)

Values are means ± SE, with n in parentheses. Applications were for 40 s followed by 4-min washout periods in HEK293 cells expressing rat P2X2a receptor.

τdes, desensitization constant; Imax, maximal ATP current.