TABLE 2.

Summary of articles included in group II and III review.

Author Group Measurement Method Study Design* Internal Validity External Validity Additional Category
Goldberg et al.[48] III Water displacement E5 Low Low Early limb, Whirl pool therapy
Manella[49] III Anthropometric E1 Moderate High Early limbs, Shrinker sock vs. EB
Fernie & Holliday[14] II Water displacement O1 Moderate Moderate Early and mature limbs
Mueller[50] III Anthropometric E1 Moderate Moderate Early limbs, RRD vs. EB
Liedberg et al.[51] II & III Anthropometric E1 Low Low Early limbs Adaptable device
Persson & Liedberg[52] II Anthropometric O5 Low Moderate Early limbs
Wilson et al.[53] III NA X2 NA NA Adaptable device
Golbranson et al.[8] II Anthropometric
Water displacement
E2 Low Moderate Correlated measurement techniques in early limbs
Pinzur et al.[54] III NA X2 NA NA Adaptable device
Maclean & Fick[9] II & III Anthropometric E2 Moderate High Early limbs SRD vs. EB
Lilja & Oberg[11] II Laser scan O5 Low High Early limbs
Lilja et al.[55] II MRI O6 Low High Early limbs
Lilja et al.[13] II Laser scan O5 Moderate Moderate Early limbs
Wong & Edelstein[10] II & III Anthropometric E1 Moderate High Early limbs, SRD vs. EB
Board et al.[56] III Casting + water displacement E5 Low Moderate Mature limbs
Vacuum-assisted suspension
Goswami et al.[57] III Casting + water displacement E5 Low Moderate Mature limbs
Vacuum-assisted suspension
Graf & Freijah[21] III Casting + water fill/displacement E1 Moderate High Mature limbs
Vacuum-assisted suspension
Greenwald et al.[58] III Fluid-filled bladders O6 Low Low Early limbs RRD vs. RRD + gel sock
Zachariah et al.[6] II Optical scan O5 High High Adaptable device
Nawijn et al.[17] III NA S2 NA NA Mature limbs
Sanders et al.[12] II Optical scan O5 Moderate High Systematic review
Sanders et al.[59] III Fluid-filled bladders O6 High High Mature limbs
Adaptable device
Singh et al.[16] II Ultrasound O1 Moderate High Early limbs
Janchai et al.[60] III Anthropometric E1 Moderate High Early limbs RRD vs. EB
Ogawa et al.[61] III Fluid-filled bladders O6 Low Low Adaptable device
Sanders et al.[7] I & II Bioimpedance O5 High High Mature limbs
*

Refer to Appendix A and Hafner[62] for study design descriptors.

NA = not applicable; MRI = magnetic resonance imaging; SXCT = spiral x-ray computer tomography; RRD = removable rigid dressing; SRD = semi-rigid dressing; EB = elastic bandage; vs. = versus.