Skip to main content
. 2014 Nov 5;35(2):193–199. doi: 10.1038/jcbfm.2014.196

Table 1. Systemic circulatory parameters before and after enteral supplement of CORM-A1 (2 mg/kg).

Experiment MABP (mm Hg) HR (beats/min) Arterial PCO2 (mm Hg) Arterial PO2 (mm Hg) pH Body temperature (°C)
Baseline 76±5 135±6 33±2 98±5 7.42±0.03 37.7±0.2
             
Time after CORM-A1
 10–20 minutes 76±6 139±9 35±3 90±9 7.39±0.04 37.5±0.2
 30–40 minutes 75±4 146±11 37±3 85±3a 7.41±0.02 37.9±0.1
 50–80 minutes 73±5 149±11 35±2 85±4a 7.41±0.03 37.8±0.3

HR, heart rate; MABP, mean arterial blood pressure. n=6 animals.

a