Skip to main content
. 2015 Jun;353(3):529–538. doi: 10.1124/jpet.114.222299

TABLE 1.

[3H]DA uptake inhibition by select SRI compounds: one-component versus two-component fits

Dose-response curves (eight points) reported in Fig. 2 were fit to one- and two-component equations for the best-fit estimates of the IC50 and Emax values (± S.D.).

Drug One-Site IC50 One-Site Emax Two-Site IC50-1 Two-Site Emax1 Two-Site IC50-2 Two-Site Emax2 Sum-of-Squares One-Site Fit Sum-of-Squares Two-Site Fit F Test
nM %I nM %I nM %I
SRI-29986 18 ± 4 75 ± 3 18 × 105 ± 1.7 × 105 37 × 108 ± 2.7 × 108 18 × 105 ± 1 × 105 37 × 108 ± 0.7 × 108 175 175 0
SRI-31335 156 ± 12 100 ± 1.5 99 ± 63 76 ± 54 564 ± 1177 27 ± 53 28.9 19.0 1.56
SRI-30835 15 ± 7 75 ± 5 6 ± 0.9 57 ± 2 4000 ± 1330 42 ± 4 677 14.2 140*
*

P < 0.001 vs. one-component fit (F test).